For your own safety, one hand must always remain free. Drager accuro measurements are often taken under extreme conditions. How to use the drager accuro gas detection pump 6400000. Drager gas detector looking drager gas detector online drager multiwarn ii manual how x am 2000 onoff youtube sep 18 2012. Sep 07, 2010 cross instrumentation draeger accuro 2000 pump and how to op dan hines. Looking for draeger accuro pump, includes pump, manual, hex wrench and tube opener 36e865. Drager accuro 2000 typ 6400200 pumpautomat 64 00200. The pump works manually and does not require the use of a power supply. Authentic draeger replacement parts for wear components of the accuro 6400000 pump including. Pdf drager accuro 2000 operation manual martha fonseca. Accuro is robust, inexpensive and easy to service, and can be operated singlehandedly. For longterm measurements dragerdiffusiontubes with. When measuring, the pump body bellows is pressed together completely.
The pump is as critical to accurate measurement as the draeger tube. Configuration to configure a device with standard configuration to meet individual requirements, connect the device via the usb infrared cable order no. Draeger accuro colorimetric manual tube pump duration. Draeger tube accuro manual pump spare parts kit 6400220. Draeger tube accuro pump best practices cross company. Second is the draeger accuro pump, which draws a calibrated, repeatable 100 ml sample of air through the tube using the manual internal bellows pump. How to use the drager accuro pump frontline safety blog. Drager accuro pump kit with case, 100 ml sample draw from cole. Buy drager accuro pump kit with case, 100 ml sample draw and more from our comprehensive selection of drager accuro pump kit covid19 update. Drger battery charger for accuro 2000 automatic pump. The drager detection tubes are glass vials filled with a chemical reagent that reacts to a specific chemical or family of chemicals. Drager xam 2000 features the latest series of powerful.
President and owner of pk safety, rick pedley shows you the trusted and reliable draeger accuro colorimetric manual tube pump. Drager xam pump the drager xam pump is an external pump for the portable gas detectors drager xam 2500, 5000, and 5600 designed for clearance measurement, for example in tanks and shafts. Gasdetection monitors and tools check for gases in an area to find leaks and help prevent exposure to hazardous gases. How to use draeger detector tubes w the drager accuro pump. Drager accuro instructions for use manual pdf download. Oxylog a time cycled, volume constant transport and emergency ventilator for patients requiring a minute volume ventilation of at least 3 liters per minute.
Drager accuro pump kit with case, 100 ml sample draw from. The cornerstone of the draeger tube system is the accuro pump. Drager gas detection pump accuro the accuro gas detection pump from drager safety works in combination with shortterm detection tubes to take gas measurements under extreme conditions. The onehanded operation is simple and allows you to reach places that a piston pump cannot go. Draeger safety 6400000 accuro pump, includes pump, manual. How to use the drager accuro gas detection pump youtube. Functional bellows pump the dragertube pump accuro draws in 100 ml per stroke. Please check the individual instructions in your pack of tubes for additional information on how many strokes, storage instructions, measurement. Cross instrumentation draeger accuro 2000 pump and how to op. Accuro pump, includes pump, manual, hex wrench and. Automatic pump drager accuro 2000 with the gas detector pump accuro. When the bellows is released, the air is drawn automatically and the gas sample to be measured is sucked through the tube being used.
Instruction manual drager msi em200s edition 20110101 4 of 33 d 950 2. Manual injector 1 mixer 3 pump 26 separations module 4 solvent degasser 6 solvent extractor 0. Welcome to my listing for this drager accuro 2000 pump gas analyzer. The following only shows the instrument version with 4 measuring channels. Drager accuro 2000 manual printable 2019 reading free at brazilfilmfestival. I have had several pieces of electrical equipment from a recent clearance of which i know nothing about or have no use for. The draeger accuro manual tube pump is a bellowsstyle hand pump used for making quick spot measurements and process checks for gas using draeger, july 11, 2008 page 5 draegertubes what is a drager accuro pump. The accuro gas detector pump is a manually operated bellows pump that draws a calibrated 100 ml sample through the shortterm drager gas detection tubes.
Draeger safety 6400000 accuro pump, includes pump, manual, allen wrench and tube opener, 20 height, 20 wide, 20 length 2. View and download drager oxylog 2000 plu instructions for use manual online. Free download books drager accuro 2000 manual printable 2019 everybody knows that reading drager accuro 2000 manual printable 2019 is helpful, because we can easily get information through the resources. The pump automatically switches on when it is connected to a running xam device. This manual pump is used for spot measurements such as the detection of concentration peaks, confined space entry.
Singlegas detection tubes contain granules that change color when exposed to a specific compound, making them ideal for. Drager detection tubes and accuro pump keison products. Hold pump so that the endofstroke indicator and the. Drager accuro 2000 gas detection system waccro pump. Drager accuro 2000 typ 6400200 pumpautomat 64 00200 ebay. Technology has developed, and reading drager accuro 2000 manual printable 2019 books may be easier and easier. To support you, coleparmer is open for business and shipping product daily. How to use the drager accuro pump and draeger detector tubes, by instrument depot. If the targeted chemicals is present the reagent in the tube. Buy drager accuro pump kit with case, 100 ml sample draw and more from our comprehensive selection of drager accuro pump kit. The drager accuro is a bellows pump, with which the air sample is drawn through the drager tube using strokes. Gas detector pump for all drager short term tubes and sampling tubes. Buyers identified defective product shall be returned to systech at buyer.
The lp1200 is a pistontype hand pump that draws a fixed volume of. General description oxylog is a purely pneumaticpowered transport and emergency ventilator. Features a onehand operation, very low maintenance, endofstroke indicator and builtin automatic stroke counter. The body of the pump consists of a bellows, which is completely pushed together for the measurement. Draeger accuro colorimetric manual tube pump youtube. With display of inspiratory airway pressure paw, with audible and visual. Detecting oxygen depletion is particularly important due to the use of nitrogen in. Oxylog 2000 plu medical equipment pdf manual download.
This manual pump is used for spot measurements such as the detection of concentration peaks, confined. Remember that the draeger accuro pump draws a calibrated, repeatable 100 ml sample of air through the tube using the manual internal bellows pump. The bellows design provides precise volume with very low maintenance. Customs services and international tracking provided. Drager tubes with the accuro pump deliver the most accurate results. Drager accuro gas detection pump top 5 things you need to. For use with shortterm detector tubes see 453238 series. Singlegas and multigas detectors are portable devices commonly used for inspecting tanks and pipelines. Gasspurpumpe accuro 64 00 000 accuro gas detector pump 64 00 000 ersatzteileset 64 00 220 spare part kit 64 00 220 handschlaufe, vollstandig 64 00 208 loop handle, complete 64 00 208 drager rohrchenoffner.
The accuro manual gas detector pump is used for spot measurements with drager tubes. It draws a calibrated 100 ml sample of air through the drager tube with each stroke. If the targeted chemicals is present the reagent in the tube changes color and the length of the color change typically indicates the measured concentration. This particular item is drager accuro 2000 pump gas analyzer. Drager accuro 2000 pump gas analyzer type 6400200, new open box. A builtin stroke counter tells you exactly how many strokes have been taken. Info free download books drager accuro 2000 manual printable 2019 everyone knows that reading drager accuro 2000 manual printable 2019 is useful, because we could get too much info online through the resources. Accuro 2000 pump, quantimeter air monitor the accuro gas detector pump is a manually operated bellows pump that draws a calibrated 100 milliliter sample through the shortterm dragertubes.
Tech tips for draeger accuro pump maintenance pump leak test in order to draw the correct 100 ml sample of air through the draeger tube, the bellows pump must be at peak performance. Accuro 2000 pump, quantimeter air monitor ark safety. Cross instrumentation draeger accuro 2000 pump and how to. Drager oxylog 2000 plu instructions for use manual pdf download. The accuro pump can easily be ope draeger accuro pump 6400000 the draeger accuro manual tube pump is a bellowsstyle hand pump used for making quick spot measurements and process checks for gas using draeger colormetric detector tubes in a wide variety of industrial workplaces. A calibrated 100 ml sample of air is drawn through the tube with the drager accuro bellows pump if the targeted chemicals is present the reagent in the tube changes colour and the length of the colour change typically. Drager accuro 2000 typ 6400200 pumpautomat 64 00200 very nice cosmetically. Find how to use the drager accuro pump, suitable for use with hundreds of gas detection tubes.
Drger battery charger for accuro 2000 automatic pump replacement battery charger gloves, glasses and safety. Drager accuro 2000 manual printable 2019drager accuro 2000 manual printable 2019 is the best ebook you want. In order to confirm your pump is in operating condition, perform a leak test following this guide. Cross instrumentation draeger accuro 2000 pump and how to op dan hines. The pharmaceutical industry requires significant gas monitoring on the production floor, in research and development laboratories, and in plant utility rooms, especially because of its use of inert or toxic chemicals in often confined spaces. Draeger safety 6400000 accuro pump, includes pump, manual, allen wrench and tube opener, 20 height, 20 wide, 20 length. Rae systems began manufacturing gas detection tubes in 1997 and is adding many new tubes to its product line each year. You can get any ebooks you wanted like drager accuro 2000 manual printable 2019 in easy step and you can get it now.
Sep 02, 2016 find how to use the drager accuro pump, suitable for use with hundreds of gas detection tubes. The instrument the msi em200s is an electronic multiple channel measuring instrument, analysing the flue gas concentrations and combustion data for engineers, service, environmental protection, etc all measurements and checks may be documented by printing or data. When you deploy the draeger tube system, for portable gas detection, your draeger accuro pump must be in spec and working correctly. A calibrated 100 ml sample of air is drawn through the tube with the drager accuro bellows pump.